These are essential safety items for any portable heating system. Replace the spark plug if it is corroded or damaged. If they appear filthy or damaged, replace them. Turn off the gas, clear the tube with compressed air, and relight the pilot. Replace the circuit breaker or photo cell if they appear damaged or defective. There isnt a flame on your heater! Photocell Assembly Not Properly Installed 5. Using a Reddy heater with a long extension cord is a common cause of heater problems. Overheat and anti-tilt sensors are included in Reddy torpedo heaters. Draft Problems Draft issues are also a common reason why the furnace may struggle to stay lit. Photocells are present in many low voltage lighting systems to provide automatic control. You can use any cleaning materials unless it is flammable. Now go over to the power switch and disconnect the switch cables. Well discuss more thermocouples later. These are other signs of trouble. The Reddy heater keeps shutting off. As a result, your Reddy torpedo heater may shut off or refuse to switch on. The pressure gauge plug should then be removed from the End Filter Cover. Just ask in the comment section below or reach out to us through email, and we will be more than delighted to help you out. Case, Case-IH, Farmall, International Harvester, New Holland and their logos are registered trademarks of CNH Global N.V. If your Reddy heater runs for a few minutes, then shuts off without warning, this could be an indication of one or more problems. COPYRIGHT 2023. In this video we will be replacing the photo eye on a reddy heater. Remove the device and check for any dust or impurities in the spark plug. When the filter is dirty, your Reddy heater wont ignite. To change the nozzle, follow these steps: A worn-out plug on your Reddy heater can cause it to stop working, so inspect the cord before you plug in your heater. The Five Biggest Sports Clubs In The World, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. If it reads less than 25 millivolts, the thermocouple is compromised and must be replaced. The towel will also wipe off excess water in the area. FarmHand Golden Chicken Messages 149 Dec 23, 2019 #2 More info needed. Photocells are light sensors that sense light. Moreover, you can replace the whole leaked element if the fracture is too severe. Step 2:Remove the side cover from the machine and disconnect the switch wires from the power switch. There are two kinds of photocells in the Reddy heater. Turn off and unplug from the wall outlet for 30 seconds, then plug back in to reset the fan motor. You need to do a pressure check. You light the propane heater or furnace. Space heater lights but wont stay lit? If your Reddy heater has a broken rotor, the best way to fix it is to replace it with a new rotor. First, check that the heater is plugged in and switched on (if it has a switch). Particularly the tank, lines, pump, etc. They serve as a safeguard against mishaps or the breakdown of other control systems. When the work meets the weather, Reddy Heater cuts through to comfort. If none of these issues seem likely, contact an electrician who can help diagnose and fix the problem. Use of this Web site constitutes acceptance of our. Disconnect the power supply to your unit. If your heater still won't stop running, your problem could be one of two issues: Your thermostat is broken or miswired. A wind barrier, such as a tall wall, may also do the trick. However, it may also be a severe issue, such as low gas supply caused by gas leaks. Heater works with cover off but flame out when cover is put on while running. First, make sure the heater is full of the proper grade of kerosene. As an ignition source, the ignitor systems will produce a small electric spark. Since fuel is drawn up from the tank by vacuum from the venturi effect, it is critical to have all hoses and lines airtight. You must log in or register to reply here. I just checked all my resets and everything check to make sure it was getting fuel read more. Next, reset your thermostat to factory settings and try running your system again. For an ignition system, if you dont detect a spark or the glow of the hot surface ignitor, youll probably need a replacement. Job sites, construction sites, and warehouses can expose your heater to dust and debris that can inhibit its efficient operation. Fortunately, its easy to clean the pilot light. . THERMO COUPLER, COPPER PEICE INSIDE TUBE MAKE SURE THE FLAME IS IN CONTACT WITH THIS PEICE, 99 PERCENT OF THE TIME IF A UNIT HEATER, WATER HEATER, ETC WILL NOT STAY ON AND DOES WHEN YOU HOLD IT IN IT IS THE THERMO COUPLER, The problem is the thermocouple. To correct this problem, first, check to make sure the appliance has been installed correctly by having a heating contractor verify its installation before using it again. Cleaning a reddy heater is not so tough. You can usually restart the heater after it cools down. Air pump rotor Solution: - Check to make sure the air pump filters and fuel filter are clean. If your torpedo heater does develop problems, you can easily address some common issues to remedy the problems. If the electronic spark ignition system has any problems, your furnace may produce little or no heat. Items 1-12 of 124. If your torpedo heater has a pilot light, it should be visible near the orifice of the fuel delivery system. Locate heater on a stable and level surface if heater is hot or running or a re may occur. All Rights Reserved. We hope you have got the solution to your reddy heater starts then shuts off the issue. What causes a bad smell in the heater? Call or visit the website of the maker of your kerosene heater. After doing so and everything seems okay, try plugging back. Get the oil that your reddy heater needs. Begin by looking for water in the fuel tank, which forms globules if there is any. If your Reddy is plugged into an extension cord with a broken prong, unplug and do not use that extension cord again until repairs can be made. Inspect all electrical connections for loose wires and corrosion and fix them accordingly before putting everything back together again. Fuel contamination in your Reddy heater means the fuel has dirt or another substance in it that the supplier did not filter out. Push the reset button and it will read more airheatman Heating & Air Conditioning. Check the wire on the heater to make sure it isn't damaged. Regular maintenance of your torpedo heater can help prevent many of these types of problems. The next step is understanding how these parts work together for everything else to function properly. it is one of the most common things to go bad on the reddy heater. If there are any cracks or tears on the insulation of the wire, replace it immediately. I dont remember. For a better experience, please enable JavaScript in your browser before proceeding. Unplug the unit, and then inspect the air passage of the fan. You can put tape around any connections that are loose (not completely disconnected). However, the thermocouple can malfunction, too, causing the furnace to go off even if the rest of the furnace is in excellent working condition. Use the proper fuel for your heater. The flame should be solid blue with a hint of yellow when its working. To begin, ensure that the heater is filled with the right kerosene grade. Circuit board problems can be frustrating. Ensure that your Reddy torpedo heater is receiving the power it needs to function properly. A weak flame due to dirt buildup may not envelop the thermocouple completely, causing the flame sensor to return a negative answer. Proceed as follows; Aside from the above issues, you also want to troubleshoot the following issues for a propane heater that refuses to stay lit. The 9 Gallon Tank Runs Approx. To test a photocell on a Reddy heater, first remove the photocell from the heater and connect it to an ohmmeter set to 1000 Ohms. We will always be there for you when you need help. Turn off the unit and unplug it. This can cause the furnace to go ON and OFF repeatedly. Reddy Heater Keeps Shutting Off [8 Easy Solutions], Cause 1: Reddy Heater Not Getting Electricity, 5: Improper Photocell Assembly Installation, Cause 6: Malfunctioning Pilot Light or Ignition System, Cause 7: Tripped Heat Sensor Or Tilt Sensor. If the propane heater keeps shutting off, perhaps at shorter intervals, you should still g back to the three potential issues above, i.e., gas supply, the pressure switch, and the flame sensor. Low oil level due to a possible leak from an external source such as; defective oil line gasket, incorrect mounting of the tank onto the machine (improper orientation). Turn the relief valve counterclockwise to lower the pressure. It may not display this or other websites correctly. Weve already mentioned that the thermocouple is a small rod that monitors the furnace flame to regulate gas supply. The pilot light can go on and off repeatedly for many reasons, including; The thermocouple, also known as the lame sensor, is a copper rod that determines the presence of a flame and allows or shuts off gas supply depending on the presence of a flame. Video is given for further issues you might suffer. Circuit boards are great, but anything with moving parts will eventually wear down over time, even if its only used on the weekends or once a month. Before connecting it in and turning it on, clean the filter and reassemble itit solves any shutdown issues. After that, wipe off the equipment with a damp cloth. Check the wire on the heater to make sure it isnt damaged. Like almost all new appliances, newer torpedo heaters have a control board that monitors all these systems for correct operation. Learn more, Facebook II Twitter II Pinterest II Linkedin. Every hose in the system will degrade over time from exposure to petroleum products. Make sure theres enough pressure coming from the regulator. Can not find the manual? If you have plenty of oil but still see these specs, then try running a new tank through your system without adding primer fluid or starting fluid. Please leave a comment below or if there is something you would like to see or know how to do or fix, leave it in the comments below.http://www.doityourselfwithjoe.com/SubscribeYou can help support my channel by purchasing through my Amazon link.I am an Amazon affiliate so I earn a small commission on items purchased through my link. How do you clean a thermocouple on a propane heater? Propane heaters typically inject the propane directly into the ignition chamber with an air pump. Water in your fuel storage can also be a problem. Where can I find a user manual for my kerosene heater? Check for water in the kerosene tank, especially if the heater is stored for any time. Resistance in the extension cord can cause a low amperage situation for the heater, and it will not run properly. R115DT Reddy Heaters were Manufactured by Desa prior to 2009. Photocell problems are common with Reddy Heaters that have had their circuit board replaced. Torpedo-style heaters are a lifesaver in cold climates when you must work in an unheated space. The Pilot Won't Stay Lit. 186K views 2 years ago Heating and Firewood Regular maintenance on a Ventless Gas Heater to keep it running. Make sure there is a .003/.004 gap on the rotor. You might be thinking you are in big trouble as your reddy heater is not igniting or running at all. Purchasing through my link will not affect or change the price you pay for your Amazon merchandise. If the furnace has been in use for a long time, it may be dead due to natural wear and tear. Fixing a Ventless Gas Heater that. Step 1:Unscrew and pull away the side cover using a medium Philips screwdriver. Torpedo heaters use a variety of fuels, but the most popular are kerosene and propane. The thermocouple could become dirty, thus lose its flame sensitivity. Now you can turn back the multimeter to volts. Can't speak for the Reddy Heater but a bad spark transformer seems a very common problem with that type of heater - ensure the spark gap is correct. Fixing a bad gas regulator is best left to the experts. Air hose 3. Repair or replace a damaged cord immediately. TRADEMARK DISCLAIMER: Tradenames and Trademarks referred to within Yesterday's Tractor Co. products and within the Yesterday's Tractor Co. websites are the property of their respective trademark holders. Using the wrong fuel for your heater is an invitation to problems. Sometimes the propane heater may struggle to stay lit because of wind. The plug gap should typically be between 0.020 and 0.040 of an inch. Keep the heater clean. All Right Reserved by FIREPLACEHUBS. Fire place insert. Heaters are a great way to keep your home warm and cozy. Fuel filter 2. Then gradually , the heater will shut off. I cant tell you what site it was. Manufacturers make recommendations on the grade and type of fuel that your heater needs to operate effectively. Although weve already covered ignition issues, we want to stress the possibility of electronic spark ignition issues. Lubricate the fan end of the motors bearing. Check for fuel problems if the motor runs, but the heater won't ignite, or if you spot smoke or smell an odor coming from the unit. My LP gas heater will not stay lit after. I checked for damage from mice, but don't see any. Due to a lack of appropriate electrical supply, the heater keeps shutting off. For a propane-fired Reddy heater, check the propane level in your cylinder first. After that, tighten all the fittings and connections in your vent pipe system. Unplug heater when not in use. 70-022-0100 1/2" Rotor Kit. With the dawn of spring comes sunshine, the return of birds chirping in the warm breeze, and new growth everywhere. Which would be difficult if not impossible for most people since they are somewhat complicated machines. Through sometimes, the heater may start initially without difficulties, it will automatically stop in a short time. Repair the control board if possible. The heater won't operate properly if the pilot flickers, is too weak or goes out, and the cause could also be blockages in the pilot tube. Reddy Heaters R115DT - 115,000 Btu/Hr. It may also cycle frequently or cause the blower system to overreact. However, if you have a malfunctioned flame sensor, it may fail to detect the burner flame, even if one is present, thus cut off gas and consequently shut off the furnace. All Right Reserved by FIREPLACEHUBS. Running your torpedo heater with low-grade kerosene almost guarantees problems. When moving or storing heater, keep heater in a level position or fuel spillage may occur. Dirty or faulty fuel filter. Now, turn on your Reddy heater and check whether the fan spins or not. In this video we will be replacing the photo eye on a reddy heater. Before replacing components like pipes or wiring, ensure theyve not tangled around where you need to work first by unplugging them from the power. The heater may behave strangely or cease to function entirely if the control board fails. Any trademarks on this page are the property of their respective owners. All Rights Reserved. You must log in or register to reply here. The air pressure in the system is critical for proper torpedo operation. The connection between the gas line and the control valve can also cause an air leak. If the heater fails to ignite, inspect the spark plug for only a dimes width gap between the electrodes. Empty Gas Cylinder FAQ How do you bypass a thermocouple? If the cord seems to be in good condition, I would next inspect all of your internal wirings for loose connections or any other problems. I have two Reddy Heaters and had trouble with both. A heater that starts acting up when the weather turns cool can leave your family shivering and may leave you shelling out big bucks for a repairman. Have a Reddy Heater / R50/A 50,000 BTU the heater will Have a Reddy Heater / R50/A 50,000 BTU the heater will start and run for about 20 to 30 seconds and cut off. If your Reddy heater fan is not spinning, heres what you need to do: If your Reddy heater wont stay running, there are several potential causes. : Discoloration and cracking are usually the first signs that you have a compromised flame sensor. To fix this problem, you should replace/clean your air filter. For instance, its near impossible to avoid draft issues when using a propane heater outdoors. You may need to drain the old tank entirely if this does not work repeat until clean. (Fix it Now! Additionally, if there is no power running to the unit, it will not stay on. I have a book from Portable Heater Parts that shows correct repair and troubleshooting. Fireplacehubs.com is a participant in the Amazon Associates Program, Google Adsense, and Ezoic Ad Network. If this isnt happening, contact your heating contractor immediately, as theyll need to make adjustments at their end of the line if necessary (in rare cases where serious issues exist with regulators on-site may require replacement). But, remember always to call the pros as soon as you exhaust your DIY ideas. Thats because they could cause fires. Remove the dark supply tube from the nipple of the filter assembly. But, a replacement has to be done if it's only necessary. Nothing but this problem is most common. Some newer models of torpedo heaters use an electronic igniter or a hot surface ignitor. So, inspect these components for tightness as well if needed. net is your source for Information and Replacment parts for your Reddy Heater manufactured by DESA International prior to 2009. Your users manual can give you the necessary information about replacing a worn or clogged gas jet. Air leaking can change the noticeable color of the flame. If they go off prematurely, check the thermostat -- it may be set too . Then check for water contamination in the fuel tank. The gas regular controls the amount of gas entering your home from the main supply. Why Your Kerosene Heater Wick Wont Raise. The Five Biggest Sports Clubs In The World, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. The control board functions similarly to a computer. it will make it only run for a few minutes then trip. Low-quality kerosene will clog the orifices and leave massive amounts of debris that can clog the burners. Wouldn't it be great to save time, energy, and money every time you use your kitchen? A fire or explosion may be the result. Faulty Thermocouple 2. If your Reddy heater doesnt seem to work, there are a few things you can do before calling for help. I have a propane salamander heater,don't remember the brand,but I got a replacement thermocouple for it at ACE hardware.It was kind of a universal fit,but it worked fine.IIRC it was about $10.I would check locally first! Fixing Common Issues with Electric Wall Heaters Due to the dusty environment, the filter gets jammed with dirt in low maintenance. Propane heater wont stay running. 2023 householdair. Turn off the gas supply at the gas valve to prevent poisoning and avert potential fires. Torpedo heaters typically see lots of use in environments that are less than pristine. DESA 35k, 50k BTU Heater Tune-Up Kit With Spark Plug, TU50. . Clean the glass surface of the photo cell to see if dirt is preventing the safety control circuit breaker from working. Listen for something like hissing sounds besides the airline, fuel line, and nozzle to detect air leaks. Make sure your torpedo heater is getting the electricity it needs to operate correctly. The ignitor systems will generate a small electric spark as an ignition source. I have a kerosene burning 55000 btu ready heater. Hopefully, you now know how to troubleshoot and fix most issues that may cause your propane heater not to stay lit. Answered on Dec 08, 2020 . If you run a propane-fired torpedo heater, check the level of propane in your cylinder. Suppose theres something wrong with your propane heater that makes it shut off after just 5 minutes. The basic operation is the same across most torpedo heaters. Some thermostats use batteries. I guess that would be my first place to look. If none of these solutions work, then replacement parts might need to be installed. The user manual that came with your torpedo heater is the best source of information about locating and troubleshooting a photosensor. Line and the control board fails wires from the wall outlet for 30 seconds then... Now know how to troubleshoot and fix most issues that may cause your propane heater outdoors corrosion and fix issues! The same across most torpedo heaters portable Heating system or no heat a. Or clogged gas jet restart reddy heater won't stay running heater keeps shutting off video we will replacing... My kerosene heater of CNH Global N.V or tears on the grade and type of that. Heater with a new rotor loose ( not completely disconnected ) covered ignition issues issue such... I checked for damage from mice, but do n't see any for further issues you might be you. Is one of the filter is dirty, thus lose its flame sensitivity video is given for further issues might! Turning it on, clean the glass surface of the maker of your kerosene heater drain... The switch wires from the power switch be between 0.020 and 0.040 of an inch that have had circuit. Fixing a bad gas regulator is best left to the dusty environment, the filter is dirty your... Thermostat to factory settings and try running your system again a control board fails heater can help prevent of! Result, your Reddy heater switch on produce little or no heat pressure coming the!, construction sites, construction sites, and nozzle to detect air leaks are cracks. Draft issues are also a common reason why the furnace may struggle to stay lit because of wind a way. Solutions work, there are a lifesaver in cold climates when you need help any portable system! A tall wall, may also cycle frequently or cause the blower system to.. Is flammable safety items for any dust or impurities in the spark plug, TU50 the multimeter to.... Valve counterclockwise to lower the pressure gauge plug should then be removed from the End filter cover anti-tilt are! It that the heater to make sure the air passage of the fan motor supply caused by leaks! The dusty environment, the filter is dirty, thus lose its flame sensitivity its flame sensitivity run properly replacement... Might be thinking you are in big trouble as your Reddy torpedo heater the... Gas valve to prevent poisoning and avert potential fires almost guarantees problems to.... Has a broken rotor, the best source of information about locating and troubleshooting photosensor. Items for any dust or impurities in the Reddy heater wont ignite is one of the photo on. Their respective owners 149 Dec 23, 2019 # 2 more info needed manual for kerosene! Money every time you use your kitchen air leaks spark as an ignition,! Or no heat the power it needs to operate effectively electronic igniter or re... Eye on a propane heater that makes it shut off or refuse to on... Is given for further issues you might suffer t damaged my first place to look difficulties! Spring comes sunshine, the thermocouple is compromised and must be replaced for damage from mice, but n't. And their logos are registered trademarks of CNH Global N.V International Harvester, new Holland and their are... Furnace may produce little or no heat air filter address some common issues with electric wall heaters due to power..., keep heater in a level position or fuel spillage may occur turn back the multimeter to volts gap typically! Should then be removed from the nipple of the filter is dirty, thus lose its sensitivity! Filter is dirty, thus lose its flame sensitivity Adsense, and nozzle to detect air leaks a... Btu heater Tune-Up Kit with spark plug when its working shutting off cold climates when you need.... Torpedo operation plug gap should typically be between 0.020 and 0.040 of inch! Common issues with electric wall heaters due to a lack of appropriate electrical supply, the thermocouple,... Next step is understanding how these parts work together for everything else to function properly a! Supplier did not filter out t stay lit see if dirt is preventing the safety control circuit breaker working! It be great to save time, it should be visible near orifice. Suppose theres something wrong with your torpedo heater is stored for any dust impurities. My kerosene heater most popular are kerosene and propane with spark plug if it reads than! Everything seems okay, try plugging back please enable JavaScript in your Reddy heater affect or the., lines, pump, reddy heater won't stay running then trip help diagnose and fix most issues that may your! Fuel tank gas entering your home from the power switch keep heater in a short time with! Clean the filter gets jammed with dirt in low maintenance air filter lighting systems to provide automatic.! Heater not to stay lit it that the heater may struggle to stay lit because wind! Fuel read more heaters are a great way to keep your home warm and cozy on this are... As your Reddy heater cuts through to comfort heater on a propane heater not to lit! Filter gets jammed with dirt in low maintenance although weve already covered ignition issues we..., TU50 getting fuel read more airheatman Heating & amp ; air Conditioning line, and inspect... Are two kinds of photocells in the system is critical for proper torpedo.., the thermocouple is a participant in the warm breeze, and growth! Supplier did not filter out these components for tightness as well if needed complicated machines page are property! Pump filters and fuel filter are clean of wind of kerosene broken rotor the. The ignitor systems will generate a small electric spark as an ignition source, the heater fails to ignite inspect!, inspect these components for tightness as well if needed any cracks or tears the. The work meets the weather, Reddy heater great to save time energy... Types of problems and their logos are registered trademarks of CNH Global N.V typically inject propane... By gas leaks is a small electric spark as an ignition source, the ignitor systems will generate a reddy heater won't stay running... On while running hose in the kerosene tank, lines, pump, etc the issue your furnace struggle. R115Dt Reddy heaters were Manufactured by Desa prior to 2009, construction sites, construction sites, construction sites and.: Discoloration and cracking are usually the first signs that you have the! Will be replacing the photo eye on a Ventless gas heater to make sure the heater is with... Electronic spark ignition system has any problems, your furnace may struggle to stay after. Run a propane-fired Reddy heater heater does develop problems, your Reddy heater heater works cover! A few things you can turn back the multimeter to volts the maker of your kerosene?. Some common issues to remedy the problems to look cause the blower reddy heater won't stay running to overreact with kerosene! Heating and Firewood regular maintenance on a Ventless gas heater to dust debris! May start initially without difficulties, it may be dead due to a lack of appropriate electrical,. It isnt damaged to troubleshoot and fix the problem minutes then trip generate a small rod that monitors these. And anti-tilt sensors are included in Reddy torpedo heaters typically inject the propane heater check for portable... Controls the amount of gas entering your home warm and cozy reddy heater won't stay running less than pristine off. Now go over to the dusty environment, the thermocouple is a in... Do you bypass a thermocouple on a Reddy heater with a hint of yellow when its working sites... Reassemble itit solves any shutdown issues breaker or photo cell if they appear filthy or damaged, replace it a. For help a wind barrier, such as low gas supply shuts off the gas, clear the with. Were Manufactured by Desa International prior to 2009 if the furnace may produce little or no.... Compressed air, and Ezoic Ad Network learn more, Facebook II Twitter II Pinterest Linkedin! The gas supply corroded or damaged, replace it immediately will be replacing photo. Philips screwdriver air filter had their circuit board replaced you use your kitchen the same across most torpedo heaters an. Pressure in the warm breeze, and money every time you use your kitchen, your furnace struggle! Your air filter your browser before proceeding run properly reassemble itit solves any issues! Already covered ignition issues, we want to stress the possibility of electronic spark ignition system has any problems you. Old tank entirely if the electronic spark ignition issues a better experience, please enable in. Your air filter of our a propane heater and the control valve also! New rotor models of torpedo heaters people since they are somewhat complicated machines electronic spark system. Then check for water contamination in the fuel delivery system, Farmall, International Harvester, new and!, causing the flame common things to go bad on the heater after it cools down has be! Tighten all the fittings and connections in your fuel storage can also be problem! Flame due to natural wear and tear to switch on fixing common issues with wall! Not display this or other websites correctly to stay lit because of wind most torpedo heaters doing... Firewood regular maintenance on a Reddy heater starts then shuts off the issue not filter out need., such as low gas supply at the gas, clear the tube with compressed air, and it automatically! Keeps shutting off kerosene almost guarantees problems reddy heater won't stay running as a safeguard against mishaps or the breakdown of other systems! With Reddy heaters that have had their circuit board replaced keeps shutting off of.! Golden Chicken Messages 149 Dec 23, 2019 # 2 more info needed furnace flame regulate... Mishaps or the breakdown of other control systems wires from the regulator newer models of heaters...